Subject(s) - thermocouple , materials science , maximum temperature , replication (statistics) , biomedical engineering , composite material , biology , physics , medicine , virology , thermodynamics
Aim To evaluate and determine intracanal temperature rises at 2 and 4 mm from the working length (WL) necessary to obtain proper replication of intracanal anatomy with gutta‐percha (GP) using the System B heat source during vertical condensation. Methodology A split‐tooth model was prepared and artificial shallow depressions were cut in the buccal canal wall 2 and 4 mm from the WL. At the same level on the palatal wall holes were drilled to adapt two thermocouples. The canal was filled using GP in a vertical condensation technique by placing the System B plugger at 2 and 4 mm from the WL in groups A and B, respectively. Two control groups in which no GP was used were carried out placing the plugger 2 and 4 mm from the WL (groups A.c and B.c, respectively) and activating the heat source. Recording of temperature rise was carried out during the filling procedure for groups A and B and during activation for control groups A.c and B.c; the highest temperatures were recorded. After each filling was completed, 3 min were allowed for the GP to cool and the model divided to reveal the filling. Images of the GP were taken with a CCD camera to evaluate the presence of replication of artificial round depressions. In control groups, the temperature was recorded for 20 s after a 3 s activation of the heat source. The rise in temperature was compared between the groups individually at each level (2 or 4 mm) and statistically analysed using one‐way anova and Fisher PLSD tests at 5% of significance level ( P  < 0.05). Results Mean temperature rises of 14 ± 3 and 12 ± 2 °C at 2 and 4 mm from the WL, respectively, were observed in group A fillings, and 4 ± 1 and 6 ± 1 °C at 2 and 4 mm, respectively, in group B fillings. Recordings at 2 mm showed significantly ( P  < 0.05) higher temperature rises with group A.c when compared with groups B and B.c. Replication of intracanal anatomy with GP was always found in group A fillings at both levels but only 4 mm from the WL in group B fillings. Conclusions Positioning the plugger close to WL and a temperature rise of 6 °C were necessary to obtain replication of intracanal anatomy. A mean temperature rise of 4 °C at 2 mm from WL (group B) resulted in no replication of intracanal anatomy. Further studies simulating clinical conditions are necessary.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here