z-logo
Premium
Rigidity and retention of carbon fibre versus stainless steel root canal posts
Author(s) -
PURTON D. G.,
LOVE R. M.
Publication year - 1996
Publication title -
international endodontic journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.988
H-Index - 119
eISSN - 1365-2591
pISSN - 0143-2885
DOI - 10.1111/j.1365-2591.1996.tb01379.x
Subject(s) - rigidity (electromagnetism) , root canal , materials science , dentistry , composite material , orthodontics , medicine
Summary Two of the main requirements of a root canal post are that it is rigid so as to resist flexing under functional load, and that it is well retained in the root. This study compared these properties in two different 1‐mm diameter root canal posts–smooth carbon fibre posts (Endopost) and serrated stainless steel posts (Parapost). Ten posts of each type were tested for rigidity in a three‐point bend test. Ten posts of each type were cemented with resin cement into the roots of endodontically treated, extracted teeth. The tensile force required to remove the posts was recorded. The Paraposts proved to be significantly more rigid under load (P < 0.001) and significantly more strongly retained in the tooth roots (P < 0.005). The Parapost appears to be a mechanically superior post for the restoration of root‐filled teeth with narrow diameter root canals.