z-logo
Premium
Evaluation of rFVIIa (NovoSeven) in Glanzmann patients with thromboelastogram
Author(s) -
LAK M.,
SCHARLING B.,
BLEMINGS A.,
SHARIFIAN R.,
MALEKI Z.,
DARAEE A.,
ARJMAND A. R.,
HEDNER U.
Publication year - 2008
Publication title -
haemophilia
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.213
H-Index - 92
eISSN - 1365-2516
pISSN - 1351-8216
DOI - 10.1111/j.1365-2516.2007.01592.x
Subject(s) - medicine , thrombasthenia , thrombelastography , thromboelastometry , recombinant factor viia , platelet , clotting time , whole blood , ex vivo , dosing , fibrinogen , haemophilia a , haemophilia , in vivo , surgery , anesthesia , pharmacology , platelet aggregation , microbiology and biotechnology , biology
Summary.  Glanzmann thrombasthenia (GT) is a rare platelet function disorder characterized by a defect in fibrinogen binding to platelet membrane glycoprotein (GP) IIb/IIIa. Recombinant FVIIa (rFVIIa) is a haemostatic agent approved for the treatment of haemophilia patients with inhibitors, patients with acquired haemophilia and in EU also for treatment of factor VII (FVII)‐deficient patients and GT patients with antibodies to GPIIb‐IIIa. The present study was conducted to evaluate the use of the whole blood test system, rotational thrombelastometry (ROTEM), in measuring the overall haemostasis potential of rFVIIa in 28 GT patients treated with rFVIIa. The correlation of administered rFVIIa and time to start fibrin formation and clot dynamic/stability was assessed and correlation to the clinical response was elucidated. Assessments were performed on predose blood samples spiked with four different concentrations of rFVIIa and whole blood samples taken at 10 and 120 min following dosing. ROTEM parameters clotting time (CT), clot formation time (CFT) and maximum clot firmness (MCF) were measured. Both ex vivo and in vivo data showed beneficial effects on CT in the presence of rFVIIa, but no effect of added rFVIIa was seen on CFT and MCF. In conclusion, the use of thrombelastography at least in the modified form of ROTEM seems to be of limited use in predicting an adequate dose of rFVIIa in GT patients. A good clinical haemostatic response was recorded in spite of the limited changes in the ROTEM pattern supporting the conclusion that ROTEM should not be the method of choice for monitoring rFVIIa therapy in Glanzmann patients.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here