Premium
Factors affecting sonic sward stick measurements: the effect of different leaf characteristics and the area of sward sampled
Author(s) -
HUTCHINGS N. J.
Publication year - 1992
Publication title -
grass and forage science
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.716
H-Index - 56
eISSN - 1365-2494
pISSN - 0142-5242
DOI - 10.1111/j.1365-2494.1992.tb02258.x
Subject(s) - transducer , materials science , acoustics , physics
Abstract Laboratory experimentation found smooth and pubescent leaf surfaces to behave as specular (mirror‐like) reflectors of ultrasound, whilst ribbed leaves behaved as an array of reflectors. It was concluded that swards composed of species with smooth, erectophile leaves would reflect ultrasound poorly and that this may explain the low sward height measurements returned by the sonic sward stick in the field when compared with the HFRO sward stick. The likely effect of species with planophile leaves such as clover is discussed. The sward surface influencing a sonic sward stick measurement was calculated to subtend a solid angle of about 43° at the transducer, equivalent to an area of about 1000 cm 2 with the transducer mounted at a height of 50 cm. However, measurements made over turves of varying sizes or over turves with cores of varying size removed found the sensitivity decreased very rapidly beyond an inner area subtending a solid angle of about 7° this is equivalent to an area of about 30 cm 2 .