Premium
Determination of histamine in human plasma: the European external quality control study 1988
Author(s) -
COSTING E.,
NEUGEBAUER E.,
KEYZER J. J.,
LORENZ W.
Publication year - 1990
Publication title -
clinical and experimental allergy
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.462
H-Index - 154
eISSN - 1365-2222
pISSN - 0954-7894
DOI - 10.1111/j.1365-2222.1990.tb02793.x
Subject(s) - histamine , chemistry , chromatography , radioimmunoassay , external quality assessment , human plasma , medicine , biochemistry , pathology
Summary There is an increasing interest in measuring human plasma histamine levels in various clinical conditions. A variety of ‘old’ and newly developed techniques are applied to meet this demand. However, the discrepancy between reported reference values for histamine in human plasma measured using this variety of techniques, suggests the existence of a certain degree of inaccuracy and imprecision. We therefore organized an external quality control study on the reliability of current histamine determinations in European laboratories. Three lyophilized plasma quality control samples, in duplicate, covering the normal and pathological range of histamine concentrations (0–45 nmol/l), two different aqueous histamine standard samples and one solvent sample were sent to 10 laboratories for the analysis of their histamine content. The following methods were used: gas chromatography‐mass spectrometry ( n = 2), enzymatic single isotopic assay ( n = 1), fluorometric‐fluoroenzymatic assay ( n = 3), radioimmunoassay ( n = 3) and high performance liquid chromatography ( n = 2). The study was performed and evaluated according to the approved recommendations (1983) of the International Federation of Clinical Chemistry (IFCC). The target values ±s.d. of the three plasma samples were: 39·5±4·6 nmol/1 (CV=ll·6%), 2·3 ± 2·2 nmol/1 (CV = 96%) and 8·9±1·5 nmol/1 (CV = 17%), respectively. The target values ±s.d. of the two aqueous samples were: 0·9±1·1 nmol/1 (CV = 120%; true value: 0·00 nmol/1) and 10·2 ± 0·5 nmol/1 (CV = 5·3%; true value: 10·0 nmol/1), respectively. A Youden plot of two unrelated plasma samples in the pathological range defined 7/11 results as accurate and precise. The Youden plot of the two unrelated aqueous samples only denned 6/11 results as accurate and precise. In general, estimating histamine concentrations within the normal range seemed to be the most difficult part of measuring histamine in human plasma samples. It is suggested to define reference standards, methods and laboratories for plasma histamine determinations.