z-logo
Premium
Detection of a molecular defect in 40 of 44 patients with haemophilia B by PCR and denaturing gradient gel electrophoresis
Author(s) -
Tartary Michel,
Vidaud Dominique,
Piao Yingchao,
Costa JeanMarc,
Bahnak Bruce R.,
Fressinaud Edith,
Congard Brigitte,
Laurian Yves,
Meyer Dominique,
Lavergne JeanMaurice,
Vidaud Michel
Publication year - 1993
Publication title -
british journal of haematology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.907
H-Index - 186
eISSN - 1365-2141
pISSN - 0007-1048
DOI - 10.1111/j.1365-2141.1993.tb03143.x
Subject(s) - microbiology and biotechnology , temperature gradient gel electrophoresis , point mutation , genetics , haemophilia b , biology , exon , nonsense mutation , frameshift mutation , intron , gene , nucleotide , transition (genetics) , mutation , haemophilia a , missense mutation , haemophilia , 16s ribosomal rna
Summary. Oligonucleotides were computer designed to amplify by the polymerase chain reaction (PCR) the coding region, splice junctions, 112 bp of the 5’flanking region and 279 bp surrounding the polyadenylation site of the factor IX gene for analysis by denaturing gradient gel electrophoresis (DGGE). Forty‐four unselected haemophilia B patients were studied of whom 24 had severe haemophilia and 20 had a mild to moderate form of the disease. Potential mutations were identified in 40 (91%) of the 44 cases. A defect could not be detected in three severe and one mild haemophiliac by DGGE analysis and direct sequencing of all the PCR fragments from these patients revealed no nucleotide alteration supporting the DGGE results. A total of 37 point mutations, two complete gene deletions and a duplication of 26 bp were found. The 37 point mutations included 35 single nucleotide substitutions, a deletion and an insertion of one nucleotide. The 35 single nucleotide substitutions included 26 missense mutations, seven nonsense mutations, a G (‐6) to A transition in the promoter region and a G (30154) to A transition within the donor splice site of the last intron. Fifteen of these nucleotide substitutions involved CpG di‐nucleotides. Fifteen point mutations were found at codons where nucleotide substitutions had not been detected before. An insertion of a single nucleotide T at position 6370 and deletion of a G at nucleotide 30845 resulted in frameshift mutations creating stop codons at amino acid positions −2 and 250, respectively. A duplication of 26 bp (17747–17772) in exon V was found in a severe haemophilia patient resulting in a termination codon in exon VI. The detection of the mutation by the combined use of PCR, DGGE and direct sequencing was important for carrier diagnosis of 20 families with no prior history of haemophilia B.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here