RELATION OF CRUSHING STRENGTH OF SILICA BRICK AT VARIOUS TEMPERATURES TO OTHER PHYSICAL PROPERTIES *
Author(s) -
Cole Sandford S.
Publication year - 1932
Publication title -
journal of the american ceramic society
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.9
H-Index - 196
eISSN - 1551-2916
pISSN - 0002-7820
DOI - 10.1111/j.1151-2916.1932.tb13896.x
Subject(s) - brick , materials science , lime , composite material , mineralogy , metallurgy , geology
The failure at elevated temperatures under constant load for silica brick is reported using the Iupuy load test apparatus. The crushing strength at 1500°F, 1800°F. 2100°F, and 2400°F is recorded, as well as the crushing strength at room temperature. The size of test piece utilized normally was 1 by 1 by 2′/2 inches. A definite relationship is shown to exist between the strength at room temperature and that at elevated temperatures. The effect of variation in lime content, bats content, and fluxes is also reported. Data were obtained on brick made from three different quartzites. Additional physical data are reported to give information concerning the properties of the brick tested.