z-logo
Premium
Improving performance of recently introduced flow cytometry‐based approach of malignant cell screening in serous cavity effusion
Author(s) -
Sun Jingfang,
Ding Shuang,
Zhu Liqiang,
Liu Yun,
Jiang Qingqing,
Song Shuang,
Chen Weimin,
Li Shibao,
Ma Ping
Publication year - 2020
Publication title -
international journal of laboratory hematology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.705
H-Index - 55
eISSN - 1751-553X
pISSN - 1751-5521
DOI - 10.1111/ijlh.13269
Subject(s) - serous fluid , ascites , effusion , medicine , receiver operating characteristic , cutoff , hematology analyzer , pleural effusion , gold standard (test) , pathology , cytology , flow cytometry , gastroenterology , immunology , surgery , physics , quantum mechanics
Microscopy has been recognized as the “gold‐standard” cellular analysis of serous cavity effusion. However, this method is time‐consuming, labor‐intensive, and requires accomplished skills. Here, we investigated the efficiency of hematology analyzer in screening malignant cells in serous cavity effusion. Methods A total of 991 serous cavity effusion samples and 370 validation specimens collected from different departments were sent to the clinical laboratory for routine cell count using the automated hematology body fluid (BF) mode and exfoliative cytology simultaneously. High‐fluorescent cells (HFCs) were measured as the relative count (HF%) and absolute count (HF#) by BF mode. Receiver operating characteristic curve analysis was combined with scattergram rules to screen malignant cells. Results HF# and HF% in malignant samples (subgroup) were significantly higher than those in benign samples, and the HF# and HF% levels were different between ascites and pleural effusion (PE). The area under the curve values were also different between ascites and PE. Positive of malignant cells was very high when the ascites or PE sample touching Rule 1 positive and either Rule 2 negative or positive. The cutoff levels of HF# were 5.5 HFC/μL on the basis of Rules 1 and 2 negative, whereas 83.5 HFC/μL on the basis of Rule 1 negative but Rule 2 positive in ascites. By contrast, the cutoff levels of HF% were 0.55 HFC/100 WBC on the basis of Rules 1 and 2 negative, whereas 4.95 HFC/100 WBC on the basis of Rule 1 negative but Rule 2 positive in PE. Conclusions Serous cavity effusion will be increasingly analyzed using the automated hematology analyzer BF mode in the future because of its rapidness and convenience. The combined application of HFC with scattergram rules is a feasible and useful approach to screen malignant cells in serous cavity effusion.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here