z-logo
Premium
Effect of dentine cutting efficiency on the lateral force created by torque‐controlled rotary instruments
Author(s) -
Deari S.,
Zehnder M.,
AlJadaa A.
Publication year - 2020
Publication title -
international endodontic journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.988
H-Index - 119
eISSN - 1365-2591
pISSN - 0143-2885
DOI - 10.1111/iej.13319
Subject(s) - root canal , materials science , premolar , post hoc , nickel titanium , dental instruments , orthodontics , reciprocating motion , lateral incisor , torque , dentistry , maxillary central incisor , composite material , molar , mechanical engineering , engineering , physics , shape memory alloy , medicine , gas compressor , thermodynamics
Aim To study the impact of dentine cutting efficiency of rotary instruments on the lateral force they create when instrumenting simulated root canals in bovine dentine. Methodology Lateral cutting efficiency of austenitic files (ProTaper Universal) was compared to that of counterparts of a reported identical geometrical design with a martensite phase component (ProTaper Gold) in bovine dentine disks ( n  = 6). Instrument shapes were studied using digital microscopy. The intracanal lateral force exerted by the two systems in simulated premolars ( n  = 9) made from bovine incisor roots containing a standardized narrow root canal of 16 mm length was monitored using a testing apparatus equipped with a torque‐controlled endodontic motor/handpiece. Data were compared using parametric statistics, alpha error  =  0.05. Results The geometrical design of the two systems under investigation was found to be identical. The martensitic nickel‐titanium rotary files had a significantly ( t ‐test , P  < 0.05) higher lateral cutting efficiency than austenitic counterparts. This difference, however, did not impact the lateral force that was created when instrumenting simulated premolar root canals. Furthermore, lateral force peaks were generated with the progressively tapered instruments under investigation towards the full working length. Even though a glide path was prepared, the first instrument in the full‐length sequence (S1) created the highest lateral force ( anova /Tukey’s HSD, P  < 0.05). Conclusions The current experimental set‐up allows the study of the lateral force generated during root canal instrumentation. This force was not influenced by the dentine cutting efficiency of the instruments under investigation, but rather by their geometrical design.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom