z-logo
Premium
The McGill Denture Satisfaction Questionnaire revisited: Exploratory factor analysis of a binational sample
Author(s) -
Souza Raphael F.,
Ribeiro Adriana B.,
Oates Thomas W.,
Feine Jocelyne S.
Publication year - 2020
Publication title -
gerodontology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.7
H-Index - 54
eISSN - 1741-2358
pISSN - 0734-0664
DOI - 10.1111/ger.12477
Subject(s) - dentures , cronbach's alpha , medicine , mastication , masticatory force , exploratory factor analysis , dentistry , construct validity , correlation , orthodontics , clinical psychology , psychometrics , mathematics , geometry
Abstract Objectives To examine the McGill Denture Satisfaction Questionnaire ( MDSQ) in terms of dimensionality, item reduction and construct validity in a binational sample of complete denture wearers. Materials and Methods We conducted secondary analyses of baseline data from two studies on implant‐retained overdentures: a quasi‐experimental study in the United States (n = 145) and a randomised trial in Brazil (n = 120). All participants wore upper/lower dentures and responded at baseline to the MDSQ items concerning their original mandibular dentures. A putative model of the MDSQ items resulted in two question subsets: (a) overall satisfaction, retention/stability, aesthetics, cleaning, speech and comfort, plus general chewing ability; (b) mastication of specific foods. Analyses focused on the internal consistency of each subset and possible item reduction, using Cronbach's alpha (Cα), inter‐item correlation and exploratory factor analysis (EFA). Results The 1st subset showed high inter‐item correlation for most question combinations and no redundancy ( r  ≤ .8). An item on cleaning had low correlation, but its removal does not increase internal consistency (Cα ≥ .83). Results were similar for both studies, with EFA showing a single significant factor (namely “overall satisfaction, lower denture”) able to explain nearly 54% of the variance. The 2nd subset also shows strong internal consistency (Cα ≥ .95) and inter‐item correlation, with a single factor representing 65% of the variation. Conclusions This study discloses the reliability and construct validity of the MDSQ for patient‐centred evaluation of complete dental prostheses in the edentulous mandible. Findings also support the use of both “overall satisfaction” and “masticatory ability” as summary scores, for improved outcome assessment.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here