z-logo
Premium
Left ventricular volumes and ejection fraction quantification using an automated three‐dimensional adaptive analytic echocardiographic algorithm in pediatric population
Author(s) -
CarvajalRivera José J.,
LópezQuintero Johanna C.,
GonzálezMenchén Cristina,
de Agustín José Alberto,
Macaya Carlos,
Pérez de Isla Leopoldo
Publication year - 2018
Publication title -
echocardiography
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.404
H-Index - 62
eISSN - 1540-8175
pISSN - 0742-2822
DOI - 10.1111/echo.14126
Subject(s) - ejection fraction , medicine , ventricle , cardiology , intraclass correlation , population , stroke volume , algorithm , heart failure , mathematics , clinical psychology , environmental health , psychometrics
The quantitative measurement of the left ventricle by echocardiography is a fundamental tool in the diagnosis and prognosis of acquired and congenital diseases in the pediatric population. The objective of this study was to validate an automated three‐dimensional adaptive analytic echocardiographic algorithm, the so‐called Heart Model ® ( HM ) in the pediatric population, using as comparators the left atrial and left ventricular volumes and left ventricular ejection fraction obtained by means of conventional 2D and 3D echocardiography. Methods Pilot study, where a population comprised of 75 consecutive patients aged 6–17 years who attended a pediatric cardiology clinic, was evaluated. Every patient underwent a conventional 2D and 3D echocardiography and an analysis using HM . Conventional 3D echo was used as the reference method. Results Seventy‐five patients were analyzed. Mean age was 11.2 (4.0) years (52.2% women). The intraclass correlation coefficient of HM vs 2D echo was poor, but it was good for the agreement between HM and 3D echo for left ventricular end‐diastolic volume ( ICC : 0.98; 95% CI : 0.97–0.99; P  < 0.001), left ventricular end‐systolic volume ICC : 0.98; 95% CI : 0.96–0.99; P  = 0.001), and left ventricular ejection fraction ( ICC : 0.87; 95% CI : 0.78–0.92; P  < 0.001). The agreement was also good for the three parameters when the analysis was performed according to body weight. Conclusions Heart Model ® is a feasible and accurate tool for the evaluation of left atrial and left ventricular volumes and left ventricular ejection fraction in pediatric population aged above 6 years.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here