z-logo
Premium
Reproducibility of heart rate recovery in patients with intermittent claudication
Author(s) -
Fecchio Rafael Yokoyama,
Chehuen Marcel,
Peçanha Tiago,
Cucato Gabriel Grizzo,
Costa Luiz Augusto Riani,
Leicht Anthony Scott,
RittiDias Raphael Mendes,
Wolosker Nelson,
Forjaz Cláudia Lúcia de Moraes
Publication year - 2018
Publication title -
clinical physiology and functional imaging
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.608
H-Index - 67
eISSN - 1475-097X
pISSN - 1475-0961
DOI - 10.1111/cpf.12452
Subject(s) - medicine , reproducibility , intraclass correlation , cardiology , coefficient of variation , intermittent claudication , population , claudication , heart rate , heart rate variability , arterial disease , blood pressure , vascular disease , clinical psychology , statistics , mathematics , environmental health , psychometrics
Summary Background Postexercise heart rate recovery ( HRR ) is a non‐invasive tool for cardiac autonomic function assessment. Reproducibility of HRR has been established in healthy subjects; however, no study has evaluated this reproducibility in clinical populations who may present autonomic dysfunction. Patients with peripheral artery disease and intermittent claudication ( IC ) often present altered cardiac autonomic function and HRR could be an interesting tool for evaluating autonomic responses to interventions in this population. Therefore, the reproducibility of HRR should be determined in this specific population. Objective To determine the reproducibility of HRR indices in patients with IC . Methods Nineteen men with IC underwent two repeated maximal treadmill tests. Raw HR and relative HRR (difference to exercise peak) indices measured at 30, 60, 120, 180, 240 and 300s of recovery were evaluated. The presence of systematic bias was assessed by comparing test and retest mean values via paired t ‐test. Reliability was assessed by intraclass correlation coefficient ( ICC ), and agreement by typical error ( TE ), coefficient of variation ( CV ) and minimal detectable difference ( MDD ). Results There were no significant differences between the test and retest values of all raw HR and relative HRR indices ( P  ≥ 0·05), except for HR120s ( P  = 0·032). All indices exhibited excellent reliability ( ICC  ≥ 0·78). Raw HR and relative HRR indices showed TEs  ≤ 6·4 bpm and MDD s ≤ 17·8 bpm. In addition, all indices showed CV s ≤ 13·2%, except HRR 30s ( CV  = 45·6%). Conclusions The current results demonstrated that most HRR indices were highly reproducible with no systematic error, excellent reliability and good agreement in patients with IC following maximal graded exercise.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here