z-logo
Premium
Accuracy of printed casts generated from digital implant impressions versus stone casts from conventional implant impressions: A comparative in vitro study
Author(s) -
Alshawaf Bahaa,
Weber Hans-Peter,
Finkelman Matthew,
El Rafie Khaled,
Kudara Yukio,
Papaspyridakos Panos
Publication year - 2018
Publication title -
clinical oral implants research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.407
H-Index - 161
eISSN - 1600-0501
pISSN - 0905-7161
DOI - 10.1111/clr.13297
Subject(s) - significant difference , articulator , dentistry , plaster casts , stereolithography , orthodontics , implant , 3d printed , impression , mathematics , computer science , biomedical engineering , materials science , medicine , surgery , statistics , world wide web , composite material
Objectives The aim of this in vitro study was to compare the accuracy of printed implant casts from digital impressions with two intra‐oral scanners (IOS) to stone casts from conventional impressions. The hypothesis was that printed casts would be more accurate than stone casts from conventional impressions. Materials and methods A mandibular stone cast with Kennedy class II edentulism was fabricated using two internal connection tissue‐level implants at 30 degrees to each other (Replace Select RP, Nobel Biocare) to serve as master. Digital impressions ( n  = 10) were made with the white light (WL) and Active Wavefront Sampling technology (AWST) IOS. The resultant standard tessellation language (STL) datasets were used to print implant casts through stereolithography (SLA) prototyping. The conventional casts ( n  = 10) were produced with splinted open tray impression technique and polyether material in type IV stone. The master cast and all groups were digitized with lab reference scanner. The test groups STL datasets were superimposed to master cast STL in inspection software (Geomagic control 2015) to calculate root‐mean‐square error. Results The conventional, WL IOS and AWST IOS groups had mean values of 53.49 μm ( SD 9.47), 108.09 μm ( SD 9.59) and 120.39 μm ( SD 5.91), respectively. The Shapiro–Wilk test showed no evidence of nonnormality ( p  = 0.131) and Levene's test showed no evidence of heterogeneity of variance ( p  = 0.518). The one‐way ANOVA demonstrated a statistically significant difference ( p  < 0.001). Tukey's honest significant difference (HSD) showed statistically significant differences between all groups: for the comparison of AWST IOS and WL IOS, the p ‐value was 0.009, and the p ‐values of the other post hoc tests were <0.001. Conclusion Printed casts generated from digital impressions for partially edentulous posterior mandibular arches had inferior accuracy to conventional stone casts fabricated from splinted open tray impressions. The printed casts from WL IOS had better accuracy compared to AWST IOS.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here