Influence of abutment material on peri‐implant soft tissues in anterior areas with thin gingival biotype: a multicentric prospective study
Author(s) -
Lops Diego,
Stellini Edoardo,
Sbricoli Luca,
Cea Niccolò,
Romeo Eugenio,
Bressan Eriberto
Publication year - 2017
Publication title -
clinical oral implants research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.407
H-Index - 161
eISSN - 1600-0501
pISSN - 0905-7161
DOI - 10.1111/clr.12952
Subject(s) - soft tissue , abutment , implant , dentistry , crown (dentistry) , calipers , dental abutments , materials science , medicine , dental prosthesis , dental implant , titanium , orthodontics , surgery , mathematics , engineering , civil engineering , geometry , metallurgy
Purpose The aim of the present clinical trial was to analyze, through spectrophotometric digital technology, the influence of the abutment material on the color of the peri‐implant soft tissue in patients with thin gingival biotype. Material and methods Thirty‐seven patients received an endosseous dental implant in the anterior maxilla. At time of each definitive prosthesis delivery, an all‐ceramic crown has been tried on gold, titanium and zirconia abutment. Peri‐implant soft‐tissue color has been measured through a spectrophotometer after the insertion of each single abutment. Also facial peri‐implant soft‐tissue thickness was measured at the level of the implant neck through a caliper. A specific software has been utilized to identify a standardized tissue area and to collect the data before the statistical analysis in Lab* color space. Δ E parameters of the selected abutments were tested for correlation with mucosal thickness. Pearson correlation test was used. Results Only 15 patients met the study inclusion criteria on peri‐implant soft‐tissue thickness. Peri‐implant soft‐tissue color was different from that around natural teeth, no matter which type of restorative material was selected. Measurements regarding all the abutments were above the critical threshold of Δ E 8.74 for intraoral color distinction by the naked eye. The Δ E mean values of gold and zirconium abutments were similar (11.43 and 11.37, respectively) and significantly lower ( P  =   0.03 and P  =   0.04, respectively) than the titanium abutment (13.55). In patients with a facial soft‐tissue thickness ≤2 mm, the Δ E mean value of gold and zirconia abutments was significantly lower than that of titanium abutments ( P  =   0.03 and P  =   0.04, respectively) and much more close to the reference threshold of 8.74. Conclusions For peri‐implant soft tissue of ≤2 mm, gold or zirconia abutments could be selected in anterior areas treatment. Moreover, the thickness of the peri‐implant soft tissue seemed to be a crucial factor in the abutment impact on the color of soft tissues with a thickness of ≤2 mm.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here