Bone quality evaluation at dental implant site using multislice CT , micro‐ CT , and cone beam CT
Author(s) -
Parsa Azin,
Ibrahim Norliza,
Hassan Bassam,
Stelt Paul,
Wismeijer Daniel
Publication year - 2015
Publication title -
clinical oral implants research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.407
H-Index - 161
eISSN - 1600-0501
pISSN - 0905-7161
DOI - 10.1111/clr.12315
Subject(s) - hounsfield scale , cone beam computed tomography , nuclear medicine , multislice , tomography , medicine , computed tomography , radiology
Objectives The first purpose of this study was to analyze the correlation between bone volume fraction ( BV / TV ) and calibrated radiographic bone density Hounsfield units ( HU ) in human jaws, derived from micro‐ CT and multislice computed tomography ( MSCT ), respectively. The second aim was to assess the accuracy of cone beam computed tomography ( CBCT ) in evaluating trabecular bone density and microstructure using MSCT and micro‐ CT , respectively, as reference gold standards. Material and methods Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro‐ CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA , USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio ® 2012, Morrisville, NC , USA), and CTA n (v1.11, SkyScan). MSCT , CBCT , and micro‐ CT scans of each mandible were matched to select the exact region of interest ( ROI ). MSCT HU , micro‐ CT BV / TV , and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Results Strong correlations were observed between CBCT and MSCT density ( r  = 0.89) and between CBCT and micro‐ CT BV / TV measurements ( r  = 0.82). Excellent correlation was observed between MSCT HU and micro‐ CT BV / TV ( r  = 0.91). However, significant differences were found between all comparisons pairs ( P  <   0.001) except for mean measurement between CBCT BV / TV and micro‐ CT BV / TV ( P  =   0.147). Conclusions An excellent correlation exists between bone volume fraction and bone density as assessed on micro‐ CT and MSCT , respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV / TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here