z-logo
Premium
Clinical and radiographic evaluation of narrow‐ vs. regular‐diameter dental implants: a 3‐year follow‐up. A retrospective study
Author(s) -
Zweers J.,
Doornik A.,
Hogendorf E. A. H.,
Quirynen M.,
Van der Weijden G. A.
Publication year - 2015
Publication title -
clinical oral implants research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.407
H-Index - 161
eISSN - 1600-0501
pISSN - 0905-7161
DOI - 10.1111/clr.12309
Subject(s) - osseointegration , medicine , dentistry , radiography , implant , retrospective cohort study , patient satisfaction , reduction (mathematics) , mandible (arthropod mouthpart) , orthodontics , surgery , geometry , mathematics , botany , biology , genus
Objectives Narrow‐diameter implants ( NDI s) are used in severely resorbed mandibles. The reduced implant diameter means a reduction in the total contact surface between the implant and bone. The question arises whether the implant can be sufficiently osseointegrated to withstand loading forces. If not, marginal bone loss can result from overload. The aim of this retrospective study was to compare clinical and radiographic measurements and patient satisfaction of NDI s with those of regular‐diameter implants ( RDI s) placed in edentulous patients to support an overdenture via either a ball or a locator connection. Material and Methods Retrospectively over a 7‐year period, a total 119 patients fulfilled the inclusion criteria and were selected for this study. The patients received two 3.3‐ or 4.1‐mm‐diameter standard titanium implants in the mandible to support an overdenture. At maintenance examinations after 1 and 3 years, clinical peri‐implant and prosthetic conditions, marginal bone ( MB ) and patient satisfaction were investigated. Results None of the 238 implants were lost during the 3‐year follow‐up period. Overall MB loss was statistically higher in the NDI group when compared with the RDI group. At the site level, a greater MB loss was observed at the distal side of both implant types. Implants with a locator showed significantly greater MB loss (0.38 mm) compared with the implants with a ball attachment (0.14 mm) over the two‐year evaluation period ( P  = 0.006). Patient satisfaction significantly favoured the NDI (8.3) and the locator attachment (8.6). Conclusions The results suggest that during the first three years after implantation, NDI s were associated with more marginal bone loss compared with RDI s. Regardless of implant diameter, the locator attachment showed more marginal bone loss over time compared with the ball attachment.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here