z-logo
Premium
Effect of different maintenance time of torque application on detorque values of abutment screws in full‐arch implant‐supported fixed prostheses
Author(s) -
AlOtaibi Hanan Nejer,
ALFouzan Afnan F.,
AlMufleh Tamadher S.,
Labban Nawaf
Publication year - 2018
Publication title -
clinical implant dentistry and related research
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.338
H-Index - 85
eISSN - 1708-8208
pISSN - 1523-0899
DOI - 10.1111/cid.12657
Subject(s) - torque , abutment , implant , orthodontics , prosthesis , dentistry , materials science , mathematics , medicine , surgery , structural engineering , engineering , physics , thermodynamics
Background The effect of different maintenance time of torque application and screw loosening in full‐arch implant‐supported prosthesis remains uninvestigated. Purpose To examine the effect of different maintenance time of torque application on detorque values of implant abutment screw in full‐arch implant‐supported fixed complete denture. Materials and methods Passively fitting framework supported by four implants stabilized on resin model torqued to 35 N‐cm and maintained for different times; instant torque application (protocol A), 10 seconds (protocol B), and 30 seconds (protocol C) were used. Detorque values were recorded during removal of the screws. Comparison between mean torque and detorque values were made using paired sample t ‐test. The mean removal torque values of each protocol were compared using three‐way analysis of variance ( ANOVA ). Results The mean removal torque values were lower than the applied torque for all the protocols. The highest mean removal torque value was found in the immediate protocol (A) (24.44 ± 1.7), followed by the 30 seconds protocol (C) (23.37 ± 1.75), and then by the 10 seconds protocol (B) (23.35 ± 1.6). All these differences were found to be statistically significant between torque and detorque values ( P  = .001). However, the differences among detorque values were not statistically significant ( P  > .05). Conclusion The application of 35 N‐cm for different maintenance time of torque application on implant abutment screw did not appear to affect the detorque value in a multiple implant‐supported fixed prosthesis. Maintaining the torque for prolonged time (10 seconds or 30 seconds) was not significantly associated with higher preload than instant torque application in full‐arch implant‐supported prosthesis.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here