z-logo
Premium
Exposure–response for biomarkers of anticoagulant effects by the oral direct thrombin inhibitor AZD0837 in patients with atrial fibrillation
Author(s) -
Lip Gregory Y. H.,
Rasmussen Lars H.,
Olsson S. Bertil,
Jensen Eva,
Hamrén Bengt,
Eriksson Ulf G.,
Wåhlander Karin
Publication year - 2015
Publication title -
british journal of clinical pharmacology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.216
H-Index - 146
eISSN - 1365-2125
pISSN - 0306-5251
DOI - 10.1111/bcp.12719
Subject(s) - medicine , atrial fibrillation , pharmacodynamics , pharmacokinetics , anticoagulant , direct thrombin inhibitor , pharmacology , thrombin , dabigatran , gastroenterology , warfarin , platelet
Aims AZD0837 is a novel oral anticoagulant investigated in clinical studies for stroke prevention in patients with atrial fibrillation (AF). It is bioconverted to its active form, AR‐H067637, a potent, specific and reversible thrombin inhibitor. The effects on coagulation biomarkers were correlated with the pharmacokinetic (PK) exposure of AR‐H067637 to guide selection of the effective dose regimen for a confirmatory efficacy study in AF patients. Methods Blood samples were obtained from 601 AF patients randomized to one of four doses of AZD0837 (blinded treatment) or dose‐adjusted vitamin K antagonists (VKA, open treatment) for 3–9 months. A pharmacodynamic model was developed to describe the time course of the AR‐H067637 exposure dependent effects and the effect of VKA on fibrin D‐dimer. The thrombin generation measured ex vivo in venous plasma was also investigated. Results The PK exposure of AR‐H067637 was stable with an interindividual variability of 33% and no or minor influence of patient demographics or comedications. For AZD0837, D‐dimer levels decreased with more rapid onset than for VKA. The decrease in D‐dimer levels correlated with steady‐state plasma concentrations ( C ss ) of AR‐H067637, with a maximum decrease of baseline D‐dimer levels estimated to approximately 60% for both AZD0837 and VKA therapy. The effect on thrombin generation correlated closely with the plasma concentration of AR‐H067637. Conclusions The effects on thrombin generation and fibrin D‐dimer levels correlated with the plasma concentration of its active form and provided comparable effects to well‐controlled VKA therapy at an exposure at least corresponding to the 300 mg once daily dose of AZD0837.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here