Comparing the predicted efficacy of one versus two supraciliary micro‐stents for lowering intraocular pressure in glaucoma patients using an ocular computational fluid dynamic model
Publication year - 2018
Publication title -
acta ophthalmologica
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.534
H-Index - 87
eISSN - 1755-3768
pISSN - 1755-375X
DOI - 10.1111/aos.13972_501
Subject(s) - glaucoma , intraocular pressure , medicine , ophthalmology , fluid pressure , mechanics , physics