z-logo
Premium
Exercise Performance of Chronic Heart Failure Patients in the Early Period of Support by an Axial‐Flow Left Ventricular Assist Device as Destination Therapy
Author(s) -
Compostella Leonida,
Russo Nicola,
Setzu Tiziana,
Compostella Caterina,
Bellotto Fabio
Publication year - 2014
Publication title -
artificial organs
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.684
H-Index - 76
eISSN - 1525-1594
pISSN - 0160-564X
DOI - 10.1111/aor.12172
Subject(s) - heart failure , ventricular assist device , medicine , cardiology , destination therapy , continuous flow , circulatory system , physics , mechanics
Axial‐flow left ventricular assist devices ( LVAD s) are increasingly used as destination therapy in end‐stage chronic heart failure ( CHF ), as they improve survival and quality of life. Their effect on exercise tolerance in the early phase after implantation is still unclear. The aim of this study was to evaluate the effect of LVAD s on the exercise capacity of a group of CHF patients within 2 months after initiation of circulatory support. Cardiopulmonary exercise test data were collected for 26 consecutive LVAD ‐implanted CHF patients within 2 months of initiation of assistance; the reference group consisted of 30 CHF patients not supported by LVAD who were evaluated after an episode of acute heart failure. Both LVAD and reference groups showed poor physical performance; LVAD patients achieved lower workload (LVAD: 36.3 ± 9.0 W, reference: 56.6 ± 18.2 W, P < 0.001) but reached a similar peak oxygen uptake (peak VO 2 ; LVAD: 12.5 ± 3.0 mL/kg/min, reference: 13.6 ± 2.9 mL/kg/min, P  = ns) and similar percentages of predicted peak VO 2 (LVAD: 48.8 ± 13.9%, reference: 54.2 ± 15.3%, P  = ns). While the values of the O 2 uptake efficiency slope were 12% poorer in LVAD patients than in reference patients (1124.2 ± 226.3 vs. 1280.2 ± 391.1; P  = ns), the kinetics of VO 2 recovery after exercise were slightly better in LVAD patients (LVAD: 212.5 ± 62.5, reference: 261.1 ± 80.2 sec, P < 0.05). In the first 2 months after initiation of circulatory support, axial‐flow LVAD patients are able to sustain a low‐intensity workload; though some cardiopulmonary exercise test parameters suggest persistence of a marked physical deconditioning, their cardiorespiratory performance is similar to that of less compromised CHF patients, possibly due to positive hemodynamic effects beginning to be produced by the assist device.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here