Out‐of‐hospital Respiratory Measures to Identify Patients With Serious Injury: A Systematic Review
Author(s) -
Daya Mohamud R.,
Cheney Tamara P.,
Chou Roger,
Fu Rongwei,
Newgard Craig D.,
O'Neil Maya E.,
Wasson Ngoc,
Hart Erica L.,
Totten Annette M.
Publication year - 2020
Publication title -
academic emergency medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.221
H-Index - 124
eISSN - 1553-2712
pISSN - 1069-6563
DOI - 10.1111/acem.14055
Subject(s) - medicine , confidence interval , triage , receiver operating characteristic , meta analysis , medline , pulse oximetry , emergency medicine , intensive care medicine , anesthesia , political science , law
Objectives The objective was to systematically review the published literature on the diagnostic accuracy of out‐of‐hospital respiratory measures for identifying patients with serious injury, focusing on measures feasible for field triage by emergency medical services personnel. Methods We searched Ovid MEDLINE, CINAHL, and the Cochrane databases from January 1, 1996, through August 31, 2017. We included studies on the diagnostic accuracy (sensitivity, specificity, and area under the receiver operating characteristic curve [AUROC]) for all respiratory measures used to identify patients with serious injury (resource use, serious anatomic injury, and mortality). We assessed studies for risk of bias and strength of evidence (SOE). We performed meta‐analysis for measures with sufficient data. Results We identified 46 articles reporting results of 44 studies. Out‐of‐hospital respiratory measures included respiratory rate, pulse oximetry, and airway support. Meta‐analysis was only possible for respiratory rate, which demonstrated a pooled sensitivity for serious injury of 13% (95% confidence interval [CI] = 5 to 29, I 2  = 97.8%), specificity of 96% (95% CI = 83 to 99, I 2  = 99.6%), and AUROC of 0.70 (95% CI = 0.66 to 0.79, I 2  = 16.6%). For oxygen saturation, sensitivity ranged from 13% to 63%; specificity, 85% to 99%; and AUROC, 0.53 to 0.76. Need for airway support had a sensitivity of 8% to 53% and specificity of 61% to 100%; studies did not report AUROC. Across respiratory measures, the SOE was low. Other respiratory measures (pH, end‐tidal carbon dioxide [CO 2 ], and sublingual partial pressure of CO 2 ) were reported only in emergency department studies. Conclusions Data on the accuracy of out‐of‐hospital respiratory measures for field triage are limited and of low quality. Based on available research, respiratory rate, oxygen saturation, and need for airway intervention all have low sensitivity, high specificity, and poor to fair discrimination for identifying seriously injured patients.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here