Analysis of Hypodermic Needles and Syringes for the Presence of Blood and Polydimethylsiloxane (Silicone) Utilizing Microchemical Tests and Infrared Spectroscopy
Author(s) -
Crowe John B.,
Lanzarotta Adam,
Witkowski Mark R.,
Andria Sara E.
Publication year - 2015
Publication title -
journal of forensic sciences
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.715
H-Index - 96
eISSN - 1556-4029
pISSN - 0022-1198
DOI - 10.1111/1556-4029.12763
Subject(s) - polydimethylsiloxane , silicone , syringe , hypodermic needle , materials science , biomedical engineering , medicine , nanotechnology , composite material , psychiatry
Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [ PDMS ]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR ‐ FT ‐ IR spectroscopy, the risk for false‐positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer‐applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS . Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection.