z-logo
Premium
Graft‐related complications and biaxial tensiometry following experimental vaginal implantation of flat mesh of variable dimensions
Author(s) -
Manodoro S,
Endo M,
Uvin P,
Albersen M,
Vláčil J,
Engels A,
Schmidt B,
Ridder D,
Feola A,
Deprest J
Publication year - 2013
Publication title -
bjog: an international journal of obstetrics and gynaecology
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.157
H-Index - 164
eISSN - 1471-0528
pISSN - 1470-0328
DOI - 10.1111/1471-0528.12081
Subject(s) - dissection (medical) , contraction (grammar) , biomedical engineering , medicine , surgery , implant , anatomy
Objective To compare the occurrence of graft‐related complications ( GRC s) and biomechanical properties of meshes implanted vaginally and abdominally. Design In vivo animal experiment. Setting Centre for S urgical T echnologies, M edical F aculty, KU Leuven, B elgium. Population Twenty adult parous T exel ewes. Methods Sheep were implanted with G ynemesh M , a 28‐g/m² polypropylene mesh reinforced with polyglecaprone fibres, under general anaesthesia. Dissection into the rectovaginal septum was performed to accommodate a flat 50 × 50 mm ( n  = 10) or 35 × 35 mm ( n  = 10) mesh, which was sutured to the underlying tissues. A 50 × 50 mm mesh was laid over a primarily sutured, full‐thickness, 40‐mm longitudinal abdominal wall incision. Sacrifice was at 60 days ( n  = 10) or 90 days ( n  = 5). Main outcome measures The occurrence of exposure, the degree of contraction and examination of the biomechanical properties of explants with a minimum radius of 32 mm via biaxial tensiometry. Results Insertion of a 50 × 50 mm mesh led to exposures in 30% (3/10) of cases, and the average contraction rate was 52 ± 14%. In the 35 × 35 mm implants, there were no exposures, and the contraction rate was 25 ± 26.3%. Vaginal explants with no GRC s and of sufficient size had biomechanical properties that were comparable with those of abdominal explants. Conclusion Vaginal mesh insertion is associated with GRC s, such as exposure and contraction. Although other factors probably play a role, this study illustrates that mesh size may also induce these complications. In a vaginal surgery model, clinically occurring GRC s can be reproduced. In addition, biomechanics of uncomplicated vaginal explants are comparable with those measured on abdominal explants.

This content is not available in your region!

Continue researching here.

Having issues? You can contact us here