Double Fed Induction Generator Shaft Misalignment Monitoring by FBG Frame Strain Sensing
Author(s) -
Yingzhao Wang,
Anees Mohammed,
Nur Sarma,
Sinisa Djurovic
Publication year - 2020
Publication title -
ieee sensors journal
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.681
H-Index - 121
eISSN - 1558-1748
pISSN - 1530-437X
DOI - 10.1109/jsen.2020.2984309
Subject(s) - signal processing and analysis , communication, networking and broadcast technologies , components, circuits, devices and systems , robotics and control systems
This study explores the potential for using FBG strain sensing to enable recognition of the shaft misalignment condition in electric machine drivetrains through observation of machine frame distributed relative strain. The sensing principles, design and installation methods of the proposed technique are detailed in the paper. The scheme was applied on a purpose built wind turbine generator representative laboratory test rig and its performance evaluated in an extensive experimental study involving a range of healthy and misaligned shaft operating conditions. The obtained experimental data demonstrate the reported method's capability to enable recognition of generator shaft misalignment conditions and thus its health monitoring. Finally, it is shown that the thermal variation of the generator frame structure inherent to its operation, combined with the FBG sensor intrinsic thermo-mechanical cross sensitivity, has no detrimental impact on the fidelity and usability of the observed strain measurements.