z-logo
open-access-imgOpen Access
Design and performance of the FBCM23 ASIC for the CMS luminosity measurement
Author(s) -
J. Kaplon,
G. Wegrzyn,
M. Obradovic,
K. Shibin
Publication year - 2025
Publication title -
ieee transactions on nuclear science
Language(s) - English
Resource type - Magazines
SCImago Journal Rank - 0.537
H-Index - 122
eISSN - 1558-1578
pISSN - 0018-9499
DOI - 10.1109/tns.2025.3596108
Subject(s) - nuclear engineering , bioengineering
We present the design and evaluation of the FBCM23 ASIC designed for the Fast Beam Condition Monitoring (FBCM) system intended for the luminosity measurements in the upgraded CMS experiment at CERN. The ASIC is implemented in a CMOS 65nm technology and consists of 6 front-end channels with a binary architecture optimized to work with 1.7×1.7mm 2 area and 290 or 150 μm thick silicon sensors. The presented ASIC will replace the existing system to comply with new, challenging specifications concerning the time resolution (1 ns rms) and noise, the latter related to the expected radiation damages of the sensors located at a radius close to 14.5 cm. The expected TID and the fluence at the end of the experiment lifetime are 200 Mrad and 2.5×10 15 n/cm 2 1MeV equivalent respectively. We present the design and a complete characterization of the ASIC, including TID irradiation, SEU tests, thermal drifts, and performance of the ASIC connected to the sensor.