Author(s) -
Ishak Ozer,
Ali Unluturk
Publication year - 2025
Publication title -
ieee access
Language(s) - English
Resource type - Magazines
SCImago Journal Rank - 0.587
H-Index - 127
eISSN - 2169-3536
DOI - 10.1109/access.2025.3587981
Subject(s) - aerospace , bioengineering , communication, networking and broadcast technologies , components, circuits, devices and systems , computing and processing , engineered materials, dielectrics and plasmas , engineering profession , fields, waves and electromagnetics , general topics for engineers , geoscience , nuclear engineering , photonics and electrooptics , power, energy and industry applications , robotics and control systems , signal processing and analysis , transportation
A current transformer (CT) is a specialized device used to reduce high current values to safe and manageable levels in measurement and protection systems. Current ratio error (CRE) is an inevitable error in CTs due to factors such as magnetic saturation, magnetic core properties, primary and secondary winding errors, temperature effects and frequency changes, and manufacturing tolerances. Keeping this error close to zero is critical to the reliability of EPS because it directly affects the operation of protective relays and the accuracy of energy measurement systems. This study has performed a field-based quantitative comparison of absolute percentage current ratio error (AP-CRE) between S-CTs and T-CTs within ARAS’s (Erzurum/Turkey) operational electric power system (EPS). The AP-CRE measurement has been obtained from S-CTs and T-CTs in EPS for protection with accuracy class 5P. Experimental measurement tests on a total of 34 CTs, including 17 S-CT and 17 T-CT, actively used in EPS. AP-CREs have been obtained by means of the TURA-01 device. In addition, during each AP-CRE measurement, absolute phase displacement (A-PD) and excitation current values have been also measured in real time. The performance of S-CT and T-CT have been evaluated based on three main metrics: mean absolute error (MAE), root mean square error (RMSE) and standard deviation (STD) values of the AP-CRE values obtained from CTs. According to AP-CRE; T-CT: MAE=0.44, RMSE=0.47 and STD=0.15, while S-CT: MAE=0.55, RMSE=0.58 and STD=0.21. The AP-CRE performance proves that T-CTs are better than S-CTs in EPS, which increases reliability.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom