z-logo
open-access-imgOpen Access
Quality indicators for blood culture: 1 year of monitoring with BacT/Alert Virtuo at a French hospital
Author(s) -
Cécile Emeraud,
Seher Yılmaz,
Nicolas Fortineau,
Gaëlle Cuzon,
Laurent Dortet
Publication year - 2021
Publication title -
journal of medical microbiology/journal of medical microbiology
Language(s) - English
Resource type - Journals
eISSN - 1473-5644
pISSN - 0022-2615
DOI - 10.1099/jmm.0.001300
Subject(s) - medicine , blood culture , clinical microbiology , emergency medicine , receipt , bloodstream infection , contamination , sample (material) , gold standard (test) , surgery , intensive care medicine , microbiology and biotechnology , biology , antibiotics , computer science , chemistry , chromatography , world wide web , ecology
. Blood culture (BC) remains the gold standard for the diagnosis of bloodstream infection. Clinical microbiology laboratories must ensure the quality of their BC process from receipt to definitive results. Aim. In this study, we followed the evolution of different quality indicators for BCs over the first year of implementation of the BacT/Alert Virtuo system in a French hospital. Methodology. In our laboratory, we instituted regular monitoring of several quality indicators to track (i) delays in sample registration, (ii) delays in loading BC bottles in our incubating system (BacT/Alert Virtuo) after registration, (iii) the volume of blood in bottles and (iv) the contamination rates. Results. For 53 892 BC bottles loaded in the BacT/Alert Virtuo from 23 January to 31 December 2019, the delays in sample registration, loading and unloading were respectively 3.5 h±0.016, 44 min±0.209 and 5.8 h±0.0727. Intriguingly, the automated process performed by the BacT/Alert Virtuo system to check the blood volume in bottles was only performed for 60 % of the loaded bottles. Among these, 30 % contained the recommended volume of blood (between 7 and 13 ml). Finally, the contamination rate was found to be 27.2 % for samples at our institution. Conclusions. The delays in sample registration, loading and unloading were found to be acceptable, even though they could be improved by ensuring a continuous service during the night duty period. Furthermore, the percentage of volumes measured is insufficient and must be improved and the majority of bottles do not contain the recommended blood volume.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here