Continuous Monitoring of Transplant Center Performance: Different Options for Different Goals
Author(s) -
Brian Alexandrine,
Émilie Savoye,
Fabienne Pessione,
C. Cantrelle,
Carine Jasseron,
Gaëlle Santin,
Olivier Bastien,
Camille Legeai
Publication year - 2019
Publication title -
transplantation
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.45
H-Index - 204
eISSN - 1534-6080
pISSN - 0041-1337
DOI - 10.1097/tp.0000000000002591
Subject(s) - cusum , medicine , alarm , cohort , control limits , statistics , emergency medicine , computer science , control chart , engineering , mathematics , process (computing) , aerospace engineering , operating system
In France, the need for continuous monitoring of transplant center performance has recently become apparent. Cumulative sum (CUSUM) monitoring of transplantation is already been used to monitor transplant outcomes in the United Kingdom and in the United States. Because CUSUM monitoring can be applied by different methods, the objective was to assess and compare the performance of different CUSUM methods for detecting higher than expected (ie, excessive) graft failure rates.