z-logo
open-access-imgOpen Access
Clinical outcomes of trabecular microbypass stent (iStent) implantation in medically controlled open-angle glaucoma in the Korean population
Author(s) -
Hee Jun Kim,
Su-Ho Lim
Publication year - 2020
Publication title -
medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.59
H-Index - 148
eISSN - 1536-5964
pISSN - 0025-7974
DOI - 10.1097/md.0000000000021729
Subject(s) - medicine , confidence interval , glaucoma medication , glaucoma , intraocular pressure , open angle glaucoma , ophthalmology , visual acuity , stent , retrospective cohort study , surgery
To evaluate the safety and efficacy [intraocular pressure (IOP)-lowering effect and medication use] of a single trabecular microbypass stent (iStent; Glaukos Corp, San Clemente, CA) for medically controlled open-angle glaucoma. This retrospective case series included 42 eyes of 34 patients with medically controlled open-angle glaucoma with IOP less than 21 mm Hg. Clinical outcomes analyzed were IOP, medication use, corrected distance visual acuity (CDVA), and surgical complications. Surgical success was defined according to 4 criteria: IOP < 21 mm Hg without medication; IOP < 18 mm Hg without medication; IOP < 15 mm Hg without medications; and IOP < 18 mm Hg with or without medication. Patients were followed for a minimum of 6 months postoperatively. Mean IOP was reduced from 15.8 ± 2.8 mm Hg to 14.5 ± 2.8 mm Hg ( P  < .001), while mean number of medications decreased from 2.2 ± 1.2 to 0.8 ± 1.1 at final visit ( P  < .001). Surgical success rates were 78.6%, 61.9%, 57.1%, and 97.6% at 6 months and 78.6%, 59.5%, 52.4%, and 95.2% at final visits according to criteria A, B, C, and D. Meanwhile, 59.5% of patients were medication-free at their final visit. The relative risk of surgical failure by Criteria B and C was 4.337 (95% confidence interval: 1.799–10.454) and 3.717 (95% confidence interval: 1.516–9.116) times greater in the higher-medication group (3 or more preoperative medications), respectively. CDVA was significantly improved from 0.41 ± 0.10 to 0.09 ± 0.07 LogMAR in the combined phacoemulsification and iStent implantation group ( P  < .001). There was no case whose vision was threatened (vision loss of 2 or more lines) or who showed severe complications after surgery. Single trabecular microbypass stent implantation was effective in reducing IOP and medication usage in patients with open-angle glaucoma with a low preoperative IOP. Our results imply that it is more difficult to achieve low target IOP control in eyes with higher numbers of preoperative medications.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here