z-logo
open-access-imgOpen Access
Clinical application of dual-phase F-18 sodium-fluoride bone PET/CT for diagnosing surgical site infection following orthopedic surgery
Author(s) -
Jeong Won Lee,
Shi Nae Yu,
Ik Dong Yoo,
Min Hyok Jeon,
Chang Hwa Hong,
Jai-Joon Shim,
Sung-Hae Chang,
Sang Mi Lee
Publication year - 2019
Publication title -
medicine
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.59
H-Index - 148
eISSN - 1536-5964
pISSN - 0025-7974
DOI - 10.1097/md.0000000000014770
Subject(s) - medicine , orthopedic surgery , nuclear medicine , bone scintigraphy , lesion , positron emission tomography , radiology , surgery
F-18 sodium-fluoride (NaF) bone positron emission tomography (PET/CT) has been used for diagnosing various bone and joint diseases, and, with using dual-phase scan protocol, it could give the same information obtained by the 3-phase bone scintigraphy. The present study aimed to evaluate the diagnostic ability of dual-phase F-18 NaF bone PET/CT in detecting surgical site infection after orthopedic surgery. Twenty-three patients who underwent dual-phase F-18 NaF bone PET/CT under clinical suspicion of surgical site infection of the bone following orthopedic surgery were enrolled in this study. Dual-phase bone PET/CT consisted of an early phase scan performed immediately after radiotracer injection and a conventional bone-phase scan. All dual-phase PET/CT images were visually assessed, and, for quantitative analysis, 6 parameters of dual-phase PET/CT (lesion-to-blood pool uptake ratio, lesion-to-bone uptake ratio, and lesion-to-muscle uptake ratio on both early phase and bone-phase scans) were measured. Surgical site infection was diagnosed in 14 patients of the 23 patients. The sensitivity, specificity, and accuracy of visual analysis of dual-phase F-18 NaF bone PET/CT for diagnosing surgical site infection of the bone were 92.9%, 100.0%, and 95.7%, respectively. Among the 6 parameters, the lesion-to-blood pool uptake ratio on early phase scan showed the highest area under the receiver operating characteristic curve value (0.857, 95% confidence interval, 0.649–0.966), with the cut-off value of 0.88 showing sensitivity, specificity, and accuracy of 85.7%, 88.9%, and 87.0%, respectively. Our study showed the high diagnostic ability of dual-phase F-18 NaF bone PET/CT for detecting surgical site infection following orthopedic surgery. Further studies are needed to compare the diagnostic ability of dual-phase bone PET/CT with other imaging modalities.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here