Determination of Intestinal Viability by Doppler Ultrasonography in Venous Infarction
Author(s) -
Marc Cooperman,
Edward W. Martin,
Larry C. Carey
Publication year - 1980
Publication title -
annals of surgery
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 4.153
H-Index - 309
eISSN - 1528-1140
pISSN - 0003-4932
DOI - 10.1097/00000658-198001000-00011
Subject(s) - medicine , occlusion , doppler ultrasound , doppler effect , small intestine , ultrasound , ultrasonography , radiology , infarction , surgery , cardiology , myocardial infarction , physics , astronomy
The accuracy of Doppler ultrasound in predicting the viability of ischemic intestine secondary to venous obstruction was assessed. Twenty loops of ischemic intestine were created in dogs by temporarily obstructing venous return from the bowel. Doppler arterial flow signals within the intestine quickly disappeared following venous occlusion. In ten segments, arterial signals promptly returned following release of venous occlusion. Nine of these ten segments were viable at reoperation 24 hours later. In ten segments, no arterial signals could be detected following release of venous occlusion, and only one segment proved to be viable. Doppler ultrasound findings were far more accurate in distinguishing between viable and nonviable intestine thatn were clinical guides to intestinal viability.