Premium
Quantitative Analysis of Corn Zeins by Capillary Electrophoresis
Author(s) -
Parris Nicholas,
Dickey Leland,
Craig James
Publication year - 1997
Publication title -
cereal chemistry
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.558
H-Index - 100
eISSN - 1943-3638
pISSN - 0009-0352
DOI - 10.1094/cchem.1997.74.6.766
Subject(s) - kjeldahl method , chemistry , capillary electrophoresis , nitrogen , chromatography , sodium dodecyl sulfate , electrophoresis , relative standard deviation , sodium , detection limit , organic chemistry
Kjeldahl analysis is commonly used to measure zein proteins in corn maize (N × 5.7) with no attempt to eliminate contribution from other nitrogen sources. In this study, dry milled corn was extracted with 70% ethanol or 0.1 N NaOH and the zein content of the extract measured using capillary electrophoresis in the presence of sodium dodecyl sulfate. The amount of zein protein in alcohol extracts, using this method, was in good agreement with that determined by Kjeldahl nitrogen analysis. However, less than half of the Kjeldahl nitrogen in the alkaline extracts could be attributed to corn zein. Reproducibility expressed as relative standard deviation for migration time and peak area was 0.10 and 1.05, respectively. The technique permits rapid analysis of a large number of samples without interference from other compounds present in the extracts.