Performance of Unobserved Self-Collected Nasal Swabs for Detection of SARS-CoV-2 by RT-PCR Utilizing a Remote Specimen Collection Strategy
Author(s) -
Ron M. Kagan,
Amy Rogers,
Gwynngelle A. Borillo,
Nigel J. Clarke,
Elizabeth M. Marlowe
Publication year - 2021
Publication title -
open forum infectious diseases
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 1.546
H-Index - 35
ISSN - 2328-8957
DOI - 10.1093/ofid/ofab039
Subject(s) - medicine , asymptomatic , interquartile range , cohort , personal protective equipment , covid-19 , disease , infectious disease (medical specialty)
Background The use of a remote specimen collection strategy employing a kit designed for unobserved self-collection for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) reverse transcription polymerase chain reaction (RT-PCR) can decrease the use of personal protective equipment (PPE) and exposure risk. To assess the impact of unobserved specimen self-collection on test performance, we examined results from a SARS-CoV-2 qualitative RT-PCR test for self-collected specimens from participants in a return-to-work screening program and assessed the impact of a pooled testing strategy in this cohort. Methods Self-collected anterior nasal swabs from employee return-to-work programs were tested using the Quest Diagnostics Emergency Use Authorization SARS-CoV-2 RT-PCR. The cycle threshold (Ct) values for the N1 and N3 N-gene targets and a human RNase P (RP) gene control target were tabulated. For comparison, we utilized Ct values from a cohort of health care provider–collected specimens from patients with and without coronavirus disease 2019 symptoms. Results Among 47 923 participants, 1.8% were positive. RP failed to amplify for 13/115 435 (0.011%) specimens. The median (interquartile range) Cts were 32.7 (25.0–35.7) for N1 and 31.3 (23.8–34.2) for N3. Median Ct values in the self-collected cohort were significantly higher than those of symptomatic but not asymptomatic patients. Based on Ct values, pooled testing with 4 specimens would have yielded inconclusive results in 67/1268 (5.2%) specimens but only a single false-negative result. Conclusions Unobserved self-collection of nasal swabs provides adequate sampling for SARS-CoV-2 RT-PCR testing. These findings alleviate concerns of increased false negatives in this context. Specimen pooling could be used for this population, as the likelihood of false-negative results is very low when using a sensitive, dual-target methodology.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom