Operator-dependent variability of angiography-derived fractional flow reserve and the implications for treatment
Author(s) -
Katherine Lal,
Rebecca Gosling,
Mina Ghobrial,
Gareth Williams,
Vignesh Rammohan,
David R. J. Hose,
Patricia V. Lawford,
Andrew Narracott,
John Fenner,
Julian Gunn,
Paul Morris
Publication year - 2021
Publication title -
european heart journal - digital health
Language(s) - English
Resource type - Journals
ISSN - 2634-3916
DOI - 10.1093/ehjdh/ztab012
Subject(s) - fractional flow reserve , medicine , intraclass correlation , operator (biology) , conventional pci , angiography , coronary artery disease , percutaneous coronary intervention , coronary angiography , radiology , statistics , cardiology , mathematics , clinical psychology , biochemistry , chemistry , repressor , myocardial infarction , transcription factor , gene , psychometrics
Aims To extend the benefits of physiologically guided percutaneous coronary intervention to many more patients, angiography-derived, or ‘virtual’ fractional flow reserve (vFFR) has been developed, in which FFR is computed, based upon the images, instead of being measured invasively. The effect of operator experience with these methods upon vFFR accuracy remains unknown. We investigated variability in vFFR results based upon operator experience with image-based computational modelling techniques. Methods and results Virtual fractional flow reserve was computed using a proprietary method (VIRTUheart) from the invasive angiograms of patients with coronary artery disease. Each case was processed by an expert (>100 vFFR cases) and a non-expert (<20 vFFR cases) operator and results were compared. The primary outcome was the variability in vFFR between experts and non-experts and the impact this had upon treatment strategy (PCI vs. conservative management). Two hundred and thirty-one vessels (199 patients) were processed. Mean non-expert and expert vFFRs were similar overall [0.76 (0.13) and 0.77 (0.16)] but there was significant variability between individual results (variability coefficient 12%, intraclass correlation coefficient 0.58), with only moderate agreement ( κ = 0.46), and this led to a statistically significant change in management strategy in 27% of cases. Variability was significantly lower, and agreement higher, for expert operators; a change in their recommended management occurred in 10% of repeated expert measurements and 14% of inter-expert measurements. Conclusion Virtual fractional flow reserve results are influenced by operator experience of vFFR processing. This had implications for treatment allocation. These results highlight the importance of training and quality assurance to ensure reliable, repeatable vFFR results.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom