Posterior Oropharyngeal Saliva for the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)
Author(s) -
Sally Cheuk Ying Wong,
Herman Tse,
Hon Kei Siu,
Tsz Shan Kwong,
Man Yee Chu,
Felix Yat Sun Yau,
Ingrid Yu-Ying Cheung,
Cindy Wing Sze Tse,
Kin Chiu Poon,
Kwok Chi Cheung,
Tak Chiu Wu,
Johnny Wai Man Chan,
Wah Cheuk,
David Christopher Lung
Publication year - 2020
Publication title -
clinical infectious diseases
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 3.44
H-Index - 336
eISSN - 1537-6591
pISSN - 1058-4838
DOI - 10.1093/cid/ciaa797
Subject(s) - medicine , confidence interval , covid-19 , saliva , respiratory system , pandemic , coronavirus , veterinary medicine , gastroenterology , disease , infectious disease (medical specialty)
Background The coronavirus disease 2019 (COVID-19) pandemic has put tremendous pressure on the healthcare system worldwide. Diagnostic testing remained one of the limiting factors for early identification and isolation of infected patients. This study aimed to evaluate posterior oropharyngeal saliva (POPS) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection among patients with confirmed or suspected COVID-19. Methods The laboratory information system was searched retrospectively for all respiratory specimens and POPS requested for SARS-CoV-2 RNA detection between 1 February 2020 and 15 April 2020. The agreement and diagnostic performance of POPS against NPsp were evaluated. Results A total of 13772 specimens were identified during the study period, including 2130 POPS and 8438 nasopharyngeal specimens (NPsp). Two hundred and twenty-nine same-day POPS-NPsp paired were identified with POPS and NPsp positivity of 61.5% (95% confidence interval [CI] 55.1–67.6%) and 53.3% (95% CI 46.8–59.6%). The overall, negative and positive percent agreement were 76.0% (95% CI 70.2–80.9%), 65.4% (95% CI 55.5–74.2%), 85.2% (95% CI 77.4–90.8%). Better positive percent agreement was observed in POPS-NPsp obtained within 7 days (96.6%, 95% CI 87.3–99.4%) compared with after 7 days of symptom onset (75.0%, 95% CI 61.4–85.2%). Among the 104 positive pairs, the mean difference in Cp value was 0.26 (range: 12.63 to −14.74), with an overall higher Cp value in NPsp (Pearson coefficient 0.579). No significant temporal variation was noted between the 2 specimen types. Conclusions POPS is an acceptable alternative specimen to nasopharyngeal specimen for the detection of SARS-CoV-2.
Accelerating Research
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom
Address
John Eccles HouseRobert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom