Fast high-resolution metabolic imaging of acute stroke with 3D magnetic resonance spectroscopy
Author(s) -
Yao Li,
Tianyao Wang,
Tianxiao Zhang,
Zengping Lin,
Yudu Li,
Rong Guo,
Yibo Zhao,
Ziyu Meng,
Jun Liu,
Xin Yu,
ZhiPei Liang,
Parashkev Nachev
Publication year - 2020
Publication title -
brain
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 5.142
H-Index - 336
eISSN - 1460-2156
pISSN - 0006-8950
DOI - 10.1093/brain/awaa264
Subject(s) - magnetic resonance imaging , medicine , stroke (engine) , magnetic resonance spectroscopic imaging , acute stroke , high resolution , nuclear medicine , penumbra , perfusion , diffusion mri , nuclear magnetic resonance , radiology , ischemia , mechanical engineering , physics , remote sensing , tissue plasminogen activator , engineering , geology
Impaired oxygen and cellular metabolism is a hallmark of ischaemic injury in acute stroke. Magnetic resonance spectroscopic imaging (MRSI) has long been recognized as a potentially powerful tool for non-invasive metabolic imaging. Nonetheless, long acquisition time, poor spatial resolution, and narrow coverage have limited its clinical application. Here we investigated the feasibility and potential clinical utility of rapid, high spatial resolution, near whole-brain 3D metabolic imaging based on a novel MRSI technology. In an 8-min scan, we simultaneously obtained 3D maps of N-acetylaspartate and lactate at a nominal spatial resolution of 2.0 × 3.0 × 3.0 mm3 with near whole-brain coverage from a cohort of 18 patients with acute ischaemic stroke. Serial structural and perfusion MRI was used to define detailed spatial maps of tissue-level outcomes against which high-resolution metabolic changes were evaluated. Within hypoperfused tissue, the lactate signal was higher in areas that ultimately infarcted compared with those that recovered (P < 0.0001). Both lactate (P < 0.0001) and N-acetylaspartate (P < 0.001) differed between infarcted and other regions. Within the areas of diffusion-weighted abnormality, lactate was lower where recovery was observed compared with elsewhere (P < 0.001). This feasibility study supports further investigation of fast high-resolution MRSI in acute stroke.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here
Accelerating Research

Address

John Eccles House
Robert Robinson Avenue,
Oxford Science Park, Oxford
OX4 4GP, United Kingdom