z-logo
open-access-imgOpen Access
Estimation of Hemoglobin A1c from Continuous Glucose Monitoring Data in Individuals with Type 1 Diabetes: Is Time In Range All We Need?
Author(s) -
Chiara Fabris,
Lutz Heinemann,
Roy W. Beck,
Claudio Cobelli,
Boris Kovatchev
Publication year - 2020
Publication title -
diabetes technology and therapeutics
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 2.142
H-Index - 88
eISSN - 1557-8593
pISSN - 1520-9156
DOI - 10.1089/dia.2020.0236
Subject(s) - medicine , target range , type 1 diabetes , calibration , glycemic , diabetes mellitus , data set , hemoglobin , metric (unit) , statistics , mathematics , endocrinology , artificial intelligence , computer science , operations management , economics
Objective: To bridge the gap between laboratory-measured hemoglobin A1c (HbA1c) and continuous glucose monitoring (CGM)-derived time in target range (TIR), introducing TIR-driven estimated A1c (eA1c). Methods: Data from Protocol 1 (training data set) and Protocol 3 (testing data set) of the International Diabetes Closed-Loop Trial were used. Training data included 3 months of CGM recordings from 125 individuals with type 1 diabetes, and HbA1c at 3 months; testing data included 9 months of CGM recordings from 168 individuals, and HbA1c at 3, 6, and 9 months. Hemoglobin glycation was modeled by a first-order differential equation driven by TIR. Three model parameters were estimated in the training data set and fixed thereafter. A fourth parameter was estimated in the testing data set, to individualize the model by calibration with month 3 HbA1c. The accuracy of eA1c was assessed on months 6 and 9 HbA1c. Results: eA1c was tracked for each individual in the testing data set for 6 months after calibration. Mean absolute differences between HbA1c and eA1c 3- and 6-month postcalibration were 0.25% and 0.24%; Pearson's correlation coefficients were 0.93 and 0.93; percentages of eA1c within 10% from reference HbA1c were 97.6% and 96.3%, respectively. Conclusions: HbA1c and TIR are reflections of the same underlying process of glycemic fluctuation. Using a model individualized with one HbA1c measurement, TIR provides an accurate approximation of HbA1c for at least 6 months, reflecting blood glucose fluctuations and nonglycemic biological factors. Thus, eA1c is an intermediate metric that mathematically adjusts a CGM-based assessment of glycemic control to individual glycation rates.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here