A Simple and Cost-Effective Method for Measuring Hemolysis in Biobank Serum Specimens
Author(s) -
Randi Elin Gislefoss,
Urszula Berge,
Marianne Lauritzen,
Hilde Langseth,
Marcin W. Wojewodzic
Publication year - 2021
Publication title -
biopreservation and biobanking
Language(s) - English
Resource type - Journals
SCImago Journal Rank - 0.545
H-Index - 34
eISSN - 1947-5535
pISSN - 1947-5543
DOI - 10.1089/bio.2021.0037
Subject(s) - hemolysis , centrifugation , turbidity , hemoglobin , turbidimetry , chromatography , chemistry , biology , immunology , biochemistry , ecology
Background: During sampling and processing, blood samples can be affected by hemolysis. Information is lacking regarding hemolysis for biobank samples. There is a need for a method that can easily measure hemoglobin as an indicator of hemolysis in stored samples before they are included in research projects. In this study we present a simple method for estimating hemolysis and investigate the effect of centrifugation speeds and temperatures on sample turbidity that commonly interferes with measurements. Methods: Using a variation of the Beer-Lambert law, we quantified the hemoglobin concentration in 75 long-term stored samples at a wavelength of 414 nm with a NanoDrop™ 8000 spectrophotometer. Owing to interference from turbidity, the samples underwent different treatments post-thawing: centrifugation at 10,000 and 20,000 g at two different temperatures (4°C and 19°C) for 15 minutes. In addition, freshly collected serum samples ( n  = 20) underwent a single freeze-thaw cycle, with hemoglobin measured prefreeze, post-thaw, and postcentrifugation. Kruskal-Wallis rank sum test groups and pairwise Wilcoxon rank test were used for statistical analysis. Results: A strong effect of centrifugation on the turbidity was shown for the long-term stored samples, however, this effect was independent of the temperature or centrifugation speeds. Centrifugation at 20,000 g for 15 minutes at 19°C reduced the turbidity up to 50%. A single freeze-thaw cycle in the fresh samples increased the optical density at 414 nm slightly, indicating a false increase of hemoglobin concentration. The following centrifugation reduced the concentration to less than the initial sample measurements, suggesting the presence of interference immediately after sampling. Conclusion: We describe here a simple and cost-effective NanoDrop-based method for measuring hemolysis levels intended for use in biobank facilities. We found that centrifugation, but not temperature, is a crucial step to reduce interference from turbidity.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here