z-logo
open-access-imgOpen Access
Solution of conjugate problem in a conical coil heat exchanger
Author(s) -
Iraida Krutova,
Ya. D. Zolotonosov
Publication year - 2020
Publication title -
iop conference series. materials science and engineering
Language(s) - English
Resource type - Journals
eISSN - 1757-899X
pISSN - 1757-8981
DOI - 10.1088/1757-899x/890/1/012156
Subject(s) - electromagnetic coil , heat exchanger , conical surface , materials science , coolant , mechanics , mechanical engineering , composite material , engineering , physics , electrical engineering
Today, coil heat exchangers are widely used in various industries. A large number of works have been published devoted to the study of the characteristics of helical coil heat exchangers. According to the authors, conical coil heat exchangers have higher efficiency compared to helical ones. The article investigates the influence of the geometric parameters of conical coil heat exchangers on their effectiveness. The object of study is a conical coil heat exchanger with different tube diameters of the inner coil (di = 13, 15, 17 mm) and various number of turns (N = 6, 10, 14). Modeling was carried out in the Ansys Fluent software package. For each combination of the parameters, data were obtained on the temperature and velocity of the coolant at the outlet. It was found that a change in the number of turns by a factor of 2.3 leads to an increase in the temperature of the heated fluid by an average of 9.7 ° C. The effect of changing the diameter of the inner coil is non-linear.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here