z-logo
open-access-imgOpen Access
A method for cantilever dental bridge material selection based upon mastication loads: finite element analysis
Author(s) -
Y. N. Kharakh,
А. Е. Крупнин,
Д. А. Грибов,
Ф. Д. Сорокин,
L. G. Kirakosyan,
S. D. Arutyunov
Publication year - 2020
Publication title -
iop conference series. materials science and engineering
Language(s) - English
Resource type - Journals
eISSN - 1757-899X
pISSN - 1757-8981
DOI - 10.1088/1757-899x/747/1/012067
Subject(s) - cantilever , mastication , von mises yield criterion , finite element method , materials science , structural engineering , bridge (graph theory) , composite material , penetration (warfare) , orthodontics , dentistry , engineering , medicine , anatomy , operations research
A method for cantilever dental bridge material selection based on mastication loads is proposed in the paper. The personalized cantilever dental bridge model was developed. Equivalent von Mises stresses investigated numerically in case of solid food segments mastication that concentrated in pontic and cantilever teeth fissures. It was shown that penetration of solid food (carrot, nut, biscuit) into cantilever tooth fissure may cause values of stresses higher than critical stresses of dental materials used. In contrast, stresses caused by penetration of food into pontic tooth fissure are not so high and proper selection of dental material may provide for required safety factor.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here