z-logo
open-access-imgOpen Access
Mechanical Properties of Single Shear Plane of Bolted Steel Connection
Author(s) -
Ahmad Fahmy Kamarudin,
Mohd Kamaruzaman Musa,
Shahrul Niza Mokhatar,
Tuan Norhayati Tuan Chik,
Sharifah Salwa Mohd Zuki,
Ab Halim Abu Bakar,
Josef Hadipramana,
Hamid Johari
Publication year - 2020
Publication title -
iop conference series. materials science and engineering
Language(s) - English
Resource type - Journals
eISSN - 1757-899X
pISSN - 1757-8981
DOI - 10.1088/1757-899x/713/1/012031
Subject(s) - fastener , tearing , structural engineering , bolted joint , ultimate tensile strength , shear (geology) , materials science , tension (geology) , composite material , bearing (navigation) , universal testing machine , engineering , finite element method , computer science , artificial intelligence
A 5-storey portable steel tower based on prefabricated frame concept has been built in Jamilus Research Centre, UTHM. It is now undergoing laboratory testing for static and dynamic performance. In this study, the mechanical properties of the connections were investigated via their connection condition between elements (beam and column) and connectors. The frame elements were designed based on S275 steel grade of 77 mm x 77 mm hollow section with 3 mm thickness, and 8 mm thickness of connectors’ plate. The connection was subjected to single shear plane action which fastened by bolts. Mild steel (grade 4.6) and high tension (grade 8.8) bolts with 10 mm diameter size were used. Shear, bearing and tensile strengths of the bolts and steel plates were determined via tension testing using 50 tonnes of Universal Testing Machine (UTM). From the results, all bolts and steel plates have satisfied the design strengths requirement of 640 N/mm 2 (high tension bolt), 240 N/mm 2 (mild steel bolt) and 275 N/mm 2 as required by EN 1993-1-8. Meanwhile the ultimate shear force of bolts was found within ranges of 25% (high tension) and 12.5% (mild steel) from their respective ultimate tensile force. Bearing failure was occurred at bolt hole of 3 mm thickness of steel plate but only when it was fastened to high tension bolt. No bearing failure occurred when mild steel bolt was used. It has proven that all bolt spacing and edges distances were sufficient, without tearing failure observed in all testing. Finally, the permissible bearing resistance were checked based on the ratio of experiment against the EN 1993-1-8 relationships, when it has shown to satisfaction if the value is less than 1 as recommended by previous researcher.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here