z-logo
open-access-imgOpen Access
Optimum Design of Transmission Coil for Giant Magnetostrictive Actuator
Author(s) -
Fanlin Zeng,
Feng Shi,
Ying Hui
Publication year - 2020
Publication title -
iop conference series. materials science and engineering
Language(s) - English
Resource type - Journals
eISSN - 1757-899X
pISSN - 1757-8981
DOI - 10.1088/1757-899x/711/1/012057
Subject(s) - electromagnetic coil , ampere , maximization , power (physics) , actuator , minification , electrical engineering , volume (thermodynamics) , power transmission , magnetostriction , acoustics , power consumption , materials science , current (fluid) , mechanical engineering , magnetic field , engineering , mathematics , physics , mathematical optimization , quantum mechanics
The driving coil is optimized by replacing the magnetic field with ampere turns. For a variety of wire diameter, select the appropriate trade-off between the ampere-number maximization and the power minimization when the volume is closest to its allowable value and does not exceed the maximum output current of the power supply. It is calculated that 1mm diameter coil has the minimum power consumption. Therefore, choose 1mm diameter enameled wire to wound coil.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here