Study on Multi-influence Factors of Dry Ice Cleaning Effect Based on Orthogonal Test Method
Author(s) -
Kuang Yin,
Jian Cong Fang,
Min Zhang,
Xin Lin,
Jiangshan Liu,
Wenjun Zhou,
Jiang Yu
Publication year - 2019
Publication title -
iop conference series. materials science and engineering
Language(s) - English
Resource type - Journals
eISSN - 1757-899X
pISSN - 1757-8981
DOI - 10.1088/1757-899x/677/2/022084
Subject(s) - nozzle , dry ice , volumetric flow rate , range (aeronautics) , rotational speed , rotation (mathematics) , flow (mathematics) , environmental science , test plan , mechanical engineering , mechanics , materials science , simulation , computer science , engineering , mathematics , composite material , geometry , statistics , physics , weibull distribution
In order to apply dry ice to the insulator cleaning in power systems, it is necessary to obtain the optimal parameter range of each of the influencing factors. In this paper, a six-factor, five-level orthogonal test method is used to obtain a representative test plan. The influence level of air pressure, dry ice flow rate, cleaning distance, cleaning time, nozzle rotation speed and cleaning time on the cleaning effect were obtained. Results revealed that the optimal range for each cleaning parameter is: air pressure 0.7MPa∼0.8MPa, dry ice flow rate 2.5kg/min∼3.0kg/min, cleaning distance 10cm∼15cm, cleaning angle 10°∼20°, nozzle rotation speed 5∼15r/min, cleaning time 30s∼36s.