Analysis on an elevator brake magnetic sleeve
Author(s) -
Facai Ren,
Qi Peng,
Xinghua Wu
Publication year - 2019
Publication title -
iop conference series. materials science and engineering
Language(s) - English
Resource type - Journals
eISSN - 1757-899X
pISSN - 1757-8981
DOI - 10.1088/1757-899x/631/4/042025
Subject(s) - elevator , brake , scanning electron microscope , materials science , microstructure , composite material , metallurgy
An elevator brake failed during use. Failure analysis was performed on magnetic sleeve of the elevator brake. The metallographic microstructure and SEM morphology of the elevator brake magnetic sleeve were investigated based on the optical microscope and scanning electron microscope analysis. The results showed that the entrance of foreign materials caused the extrusion wear to local area of the inner surface of the magnetic sleeve.