z-logo
open-access-imgOpen Access
Comparative analysis of two seismic energy dissipation solutions in the case of a steel structure
Author(s) -
F Țepeş-Onea,
Dragoş-Florian Vintilă,
Cristina Tudose
Publication year - 2021
Publication title -
iop conference series. materials science and engineering
Language(s) - English
Resource type - Journals
eISSN - 1757-899X
pISSN - 1757-8981
DOI - 10.1088/1757-899x/1138/1/012042
Subject(s) - dissipation , structural engineering , rigidity (electromagnetism) , diagonal , braced frame , joint (building) , brace , point (geometry) , beam (structure) , frame (networking) , column (typography) , seismic energy , seismic analysis , steel frame , ductility (earth science) , bending , computer science , engineering , materials science , mathematics , geometry , mechanical engineering , physics , connection (principal bundle) , composite material , thermodynamics , creep
The present paper aims at the comparative analysis of two seismic energy dissipation solutions for a steel structure in frames. We opted for non-braced frames and centrally braced frames. In the case of unbroken frames, the resistance structure consists of steel beams and columns. Potential plastic areas are formed mainly at the ends of the rulers and, to a lesser extent, in columns. Horizontal actions are mainly taken by bending the structural elements. To ensure the most efficient observance of the rigidity requirements for lateral actions, the solution of the rigid beam-column joint is required. The use of the concept of weak beam-strong column leads to the appearance of plastic joints in the beams, close to their joints with the columns. Centric braced frames can take over the horizontal actions, which are manifested in their plane, through axial forces. Energy dissipation occurs mainly by plasticizing the extended diagonals. The comparative analysis consists of highlighting the results obtained from the structural calculation with the help of a commercial automatic calculation program for the two solutions: non-braced frames and centrally braced frames. An office building with 2 levels was analyzed, located in Constanta, where the two types of the staff were provided in turn. The obtained results will be compared from the point of view of the amount of steel used, so from the economic point of view. Another comparison refers to the displacements to SLS and SLU and to the seismic energy dissipation capacity. Finally, another possible comparison refers to the over-resistance of the structural system.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here