z-logo
open-access-imgOpen Access
Adhesion Strength of Hydroxyapatite Coating on Titanium Alloy (Ti-6Al-4V ELI) for Biomedical Application
Author(s) -
B. Gunawarman,
Jon Affi,
Agus Sutanto,
Dian Mustika Putri,
Dian Juliadmi,
Nuzul Ficky Nuswantoro,
Hidayatul Fajri,
Djong Hon Tjong,
Menkher Manjas
Publication year - 2021
Publication title -
iop conference series. materials science and engineering
Language(s) - English
Resource type - Journals
eISSN - 1757-899X
pISSN - 1757-8981
DOI - 10.1088/1757-899x/1062/1/012031
Subject(s) - coating , materials science , biocompatibility , electrophoretic deposition , layer (electronics) , titanium , composite material , adhesion , surface roughness , paint adhesion testing , titanium alloy , osseointegration , deposition (geology) , alloy , metallurgy , implant , surgery , medicine , paleontology , sediment , biology
Implantation using titanium Ti-6Al-4V ELI still has disadvantages, in particular, low osseointegration cause of less bioactive of the material. Hydroxyapatite was then applied as a coating material to increase the bioactivity and the osseonintegration as well. The Ti-6AL-4V ELI samples were coated with the hydroxyapatite using the electrophoretic deposition (EPD) method, with voltage variations of 5, 8 and 11 volts for 5 minutes and variations in deposition time for 5,8 and 11 minutes with voltage of 8 volt. Surface properties (coarseness, coating mass, thickness, and surface coverage) were then determined by using related equipments. Adhesion strength the HA layer was tested a cross-cut test method. The results showed that the EPD could be used properly to coat the Ti-6Al-4V ELI material with hydroxyapatite. Voltage and deposition time influence coating layer properties that is related to adhesion bonding of the layer on the metal surface. Applying the voltage of 8 volt for 5 minutes resulted in optimal surface properties with coating roughness of hydroxyapatite layer (Ra) as much as 0.88. The removed area after the cross-cut tape test is 2.25%, which means adhesion strength between the coating layer and the subtrate is high enough. A relatively high hydroxyapatite mass (0.3 mg), is covering the material surface with a surface coverage of 82.1%, and the average coating thickness is 73.3 μm. Such kind of coating layer characteristics could improve bioactivity, biocompatibility and thus enhancing osseonintegration capacity of prosthetic medical implants.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here