Evaluation of compacted lateritic soil – bacillus coagulans induced calcite precipitate for landfill application using bacterial foraging optimization algorithm
Author(s) -
Paul Yohanna,
Kolawole J. Osinubi,
Adrian O. Eberemu,
T. S. Ijimdiya,
Ahmed Tijani Salawudeen
Publication year - 2021
Publication title -
iop conference series. materials science and engineering
Language(s) - English
Resource type - Journals
eISSN - 1757-899X
pISSN - 1757-8981
DOI - 10.1088/1757-899x/1036/1/012029
Subject(s) - bacillus coagulans , hydraulic conductivity , void ratio , bulk density , coefficient of determination , soil science , water content , materials science , geotechnical engineering , environmental science , geology , soil water , mathematics , paleontology , statistics , bacteria
Evaluation of compacted lateritic soil – Bacillus coagulans (B.coagulans) induced calcite precipitate for landfill application was carried out using Bacterial Foraging Optimization Algorithm (BFOA). Experimental results were obtained through laboratory tests. Measured soil factors include; Coefficient of permeability (hydraulic conductivity) as a dependent factor and void ratio, bulk density, B. coagulans suspension, pH, Compactive effort, water content relative to optimum, plasticity index, viscosity of microbes and liquid limit as self-determining (independent) factors. GeneXproTools 5.0 software was used to develop the fitness (objective) function used for Bacterial Foraging Optimization (BFO) to predict hydraulic conductivity of treated lateritic soil with B. coagulans suspension density. The fitness function was then integrated using BFO codes in Matlab 2016 version to predict the minimum hydraulic conductivity for a given set of self-determining factors. The result shows a strong association between the predicted hydraulic conductivity values and the measured hydraulic conductivity values in the laboratory using a regressed line with coefficient of determination R=0.85. It is clear from the optimization results that the hydraulic conductivity values and the self-determining variables have strong correlation. The least hydraulic conductivity value of 2.38×10 −11 m/s which falls below the permissible regulatory value of 1.0×10 −9 m/s for landfill application was achieved at 100 iterations. Based on all the optimization results, it is recommended that lateritic soil- B.coagulans mixtures be compacted with 1.20×10 −9 - 2.40×10 −9 cells/ml B.coagulans suspension density compacted using Britsh standard heavy (BSH) energy at 15.3 % moisture content for landfill application.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here