z-logo
open-access-imgOpen Access
Water treatment of surface water using a ferrite reagent
Author(s) -
А. С. Овчинников,
М А Денисова,
Viktor Bocharnikov,
О. В. Бочарникова,
Yu.V. Kuznetsov,
T V Repenko,
Е. В. Пустовалов
Publication year - 2022
Publication title -
iop conference series. earth and environmental science
Language(s) - English
Resource type - Journals
eISSN - 1755-1307
pISSN - 1755-1315
DOI - 10.1088/1755-1315/996/1/012002
Subject(s) - reagent , hydrocyclone , impurity , dewatering , materials science , settling , ferrite (magnet) , water treatment , chemistry , chromatography , environmental science , environmental engineering , composite material , engineering , physics , geotechnical engineering , organic chemistry , classical mechanics
The article presents the research results for a water treatment technology that removes chemical impurities with a ferrite reagent. The process scheme is a hydrocyclone filter for preliminary water purification from large suspensions, a vertical settler, a chamber for mixing the components of the reagent and a centrifuge for sludge dewatering, which can be used as a magnet. In the course of the experiments, the required cooling time intervals were established and the absorption effect of the ferrite reagent with respect to chemical impurities was determined. The settling was carried out at various intervals for 0.3, 1, 2 and 4 hours. It was found that the maximum permissible concentration of impurities in the test water was achieved within 2 hours of settling at a dose of 50 ml.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here