Interconnected operation of the ozone generator with the power supply unit
Author(s) -
M Ibragimov,
Iroda Tadjibekova,
Oybek Matchonov
Publication year - 2021
Publication title -
iop conference series. earth and environmental science
Language(s) - English
Resource type - Journals
eISSN - 1755-1307
pISSN - 1755-1315
DOI - 10.1088/1755-1315/939/1/012002
Subject(s) - transformer , oscillograph , waveform , electrical engineering , inductance , generator (circuit theory) , ozone , voltage , power (physics) , engineering , physics , meteorology , quantum mechanics
This article is addressed to the inductivity of the feeder transformer influence on of the plate-type ozone generator operating modes. The equation characterises the ozone generator interconnected operation with the transformer, in discharge and non-discharge modes is represented. Use of the near-resonant mode of operation is proposed with a view to reach maximum output capacity. With that end in view, it is proposed to use the transformer with higher inductance. Oscillograph charts of two modes of operation of the ozone generator are analysed. Current waveform factors are determined by the harmonic analysis method. Experiments proved that current waveform factor increase in value for the account of continuous discharge is conductive to increase of ozone output by 25-30 % and power loss reduction by 10-15 %.