Subject(s) - incineration , air quality index , environmental science , index (typography) , air monitoring , air pollution , waste management , environmental engineering , environmental monitoring , waste to energy , meteorology , engineering , geography , computer science , chemistry , organic chemistry , world wide web
Ambient air quality monitoring at waste-to-energy incineration pilot plant PLTSa Bantargebang is performed using a mobile monitoring station. The mobile monitoring station is equipped with meteorological and emission (CO, O 3 , NO 2 , PM 10 , PM 2.5 , and SO 2 ) measurement. The monitoring was performed for 24 hour with 1 minute intervals. The emission measurement data was analyzed using Indonesian Air pollution standard index regulation (PermenLHK P.14/2020). The CO, O 3 , NO 2 , PM 10 , and SO 2 index were in good category (1-50), while the PM2.5 index was classified as moderate (65.992). The results show that the air quality at PLTSa Bantargebang is still acceptable for human health.