z-logo
open-access-imgOpen Access
The air quality index based on measurements of mobile air quality monitoring station at the waste-to-energy incineration plant PLTSa Bantargebang
Author(s) -
I Putu Angga Kristyawan,
Wiharja,
Shamim Ahmad,
P A Hendrayanto,
Arga Santoso,
Nawa Suwedi
Publication year - 2021
Publication title -
iop conference series. earth and environmental science
Language(s) - English
Resource type - Journals
eISSN - 1755-1307
pISSN - 1755-1315
DOI - 10.1088/1755-1315/926/1/012015
Subject(s) - incineration , air quality index , environmental science , index (typography) , air monitoring , air pollution , waste management , environmental engineering , environmental monitoring , waste to energy , meteorology , engineering , geography , computer science , chemistry , organic chemistry , world wide web
Ambient air quality monitoring at waste-to-energy incineration pilot plant PLTSa Bantargebang is performed using a mobile monitoring station. The mobile monitoring station is equipped with meteorological and emission (CO, O 3 , NO 2 , PM 10 , PM 2.5 , and SO 2 ) measurement. The monitoring was performed for 24 hour with 1 minute intervals. The emission measurement data was analyzed using Indonesian Air pollution standard index regulation (PermenLHK P.14/2020). The CO, O 3 , NO 2 , PM 10 , and SO 2 index were in good category (1-50), while the PM2.5 index was classified as moderate (65.992). The results show that the air quality at PLTSa Bantargebang is still acceptable for human health.

The content you want is available to Zendy users.

Already have an account? Click here to sign in.
Having issues? You can contact us here